{"id":190,"date":"2024-02-15T11:11:00","date_gmt":"2024-02-15T10:11:00","guid":{"rendered":"https:\/\/www.buehnen.de\/international\/blog\/?p=190"},"modified":"2024-01-03T07:06:27","modified_gmt":"2024-01-03T06:06:27","slug":"repair-and-rapid-help-remove-fully-reacted-cartridges-from-the-hb-720-k","status":"publish","type":"post","link":"https:\/\/www.buehnen.de\/international\/blog\/2024\/02\/15\/repair-and-rapid-help-remove-fully-reacted-cartridges-from-the-hb-720-k\/","title":{"rendered":"Repair and rapid help: Remove fully reacted cartridges from the HB 720 K"},"content":{"rendered":"\n<p><strong><strong>A guide to efficient problem solving<\/strong><\/strong><\/p>\n\n\n\n<p><em>\u201cOh, just those few drops!\u201d<\/em> is what some people think when removing cartridges from the HB 720 K devices. But this idea can be costly when it comes to hot-melt adhesives, which, as we know, does not make any difference whether it spreads in the handheld device or lands on the substrate to be bonded. &nbsp;For this reason, contamination of the device with reactive PUR\/POR adhesives must be avoided at all costs. Heavier or more frequent contamination can lead to the destruction of the manual application device.<\/p>\n\n\n\n<p>There is, however, a simple trick to avoid damage: <strong>Hold the device with the cartridge to be removed upside down for a moment before removing it!<\/strong> &nbsp;If there is a small residue of hot-melt adhesive in the nozzle, it will flow back out of the device into the cartridge. When removing the cartridge, continue to hold the device upside down so that the cartridge can be safely removed from the coated tank.<\/p>\n\n\n\n<p><strong>Removing old cartridges made easy<\/strong><\/p>\n\n\n\n<p>However, if the reactive adhesive has leaked into the tank and reacted there, it will sit tighter in the tank. A quick repair is necessary here, and this is what you need:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>a 3.0 Allen key<\/li>\n\n\n\n<li>a small hammer<\/li>\n\n\n\n<li>a small screwdriver<\/li>\n\n\n\n<li>a replacement nozzle<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-jetpack-slideshow aligncenter\" data-effect=\"slide\"><div class=\"wp-block-jetpack-slideshow_container swiper-container\"><ul class=\"wp-block-jetpack-slideshow_swiper-wrapper swiper-wrapper\"><li class=\"wp-block-jetpack-slideshow_slide swiper-slide\"><figure><img decoding=\"async\" alt=\"\" class=\"wp-block-jetpack-slideshow_image wp-image-1393\" data-id=\"1393\" src=\"https:\/\/www.buehnen.de\/blog\/wp-content\/uploads\/2023\/12\/Hb-720-K_05-1024x662.jpg\"\/><figcaption class=\"wp-block-jetpack-slideshow_caption gallery-caption\">Unscrew the nozzle. Carefully remove the O-ring LDN0123 with the help of a screwdriver. <\/figcaption><\/figure><\/li><li class=\"wp-block-jetpack-slideshow_slide swiper-slide\"><figure><img decoding=\"async\" alt=\"\" class=\"wp-block-jetpack-slideshow_image wp-image-1399\" data-id=\"1399\" src=\"https:\/\/www.buehnen.de\/blog\/wp-content\/uploads\/2023\/12\/Hb-720-K_04-2-918x1024.jpg\"\/><figcaption class=\"wp-block-jetpack-slideshow_caption gallery-caption\">Pull the plastic cap (bead cap H219003) off the nozzle kit.<\/figcaption><\/figure><\/li><li class=\"wp-block-jetpack-slideshow_slide swiper-slide\"><figure><img decoding=\"async\" alt=\"\" class=\"wp-block-jetpack-slideshow_image wp-image-1396\" data-id=\"1396\" src=\"https:\/\/www.buehnen.de\/blog\/wp-content\/uploads\/2023\/12\/Hb-720-K_03-1024x718.jpg\"\/><figcaption class=\"wp-block-jetpack-slideshow_caption gallery-caption\">Then loosen the two screws KDN0728 on the nozzle kit. This can then be pulled out as a single unit.<\/figcaption><\/figure><\/li><li class=\"wp-block-jetpack-slideshow_slide swiper-slide\"><figure><img decoding=\"async\" alt=\"\" class=\"wp-block-jetpack-slideshow_image wp-image-1397\" data-id=\"1397\" src=\"https:\/\/www.buehnen.de\/blog\/wp-content\/uploads\/2023\/12\/Hb-720-K_02-1024x771.jpg\"\/><figcaption class=\"wp-block-jetpack-slideshow_caption gallery-caption\">The neck of the cartridge is now visible. Lightly tap the cartridge opening with the hammer. In this way, you release the cartridge to be removed from the tank.<\/figcaption><\/figure><\/li><li class=\"wp-block-jetpack-slideshow_slide swiper-slide\"><figure><img decoding=\"async\" alt=\"\" class=\"wp-block-jetpack-slideshow_image wp-image-1398\" data-id=\"1398\" src=\"https:\/\/www.buehnen.de\/blog\/wp-content\/uploads\/2023\/12\/Hb-720-K_01-1024x801.jpg\"\/><figcaption class=\"wp-block-jetpack-slideshow_caption gallery-caption\">The cartridge can now be removed using the cartridge pliers. Remove the remaining adhesive residue from the coated tank with a wooden spatula. If necessary, replace the complete nozzle kit, as the fully reacted adhesive can be everywhere. Reassemble the device in reverse order. Do not use the old nozzle, but insert a new one instead. <\/figcaption><\/figure><\/li><\/ul><a class=\"wp-block-jetpack-slideshow_button-prev swiper-button-prev swiper-button-white\" role=\"button\"><\/a><a class=\"wp-block-jetpack-slideshow_button-next swiper-button-next swiper-button-white\" role=\"button\"><\/a><a aria-label=\"Pause Slideshow\" class=\"wp-block-jetpack-slideshow_button-pause\" role=\"button\"><\/a><div class=\"wp-block-jetpack-slideshow_pagination swiper-pagination swiper-pagination-white\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A guide to efficient problem solving \u201cOh, just those few drops!\u201d is what some people think when removing cartridges from the HB 720 K devices. But this idea can be costly when it comes to hot-melt adhesives, which, as we know, does not make any difference whether it spreads in the handheld device or lands on the substrate to be [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[28],"tags":[],"class_list":["post-190","post","type-post","status-publish","format-standard","hentry","category-service"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/posts\/190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/comments?post=190"}],"version-history":[{"count":1,"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/posts\/190\/revisions"}],"predecessor-version":[{"id":191,"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/posts\/190\/revisions\/191"}],"wp:attachment":[{"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/media?parent=190"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/categories?post=190"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.buehnen.de\/international\/blog\/wp-json\/wp\/v2\/tags?post=190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}